As the temperature of the pvc increases the pressure that the pvc can withstand will decrease.
Schedule 80 pvc pressure rating.
Gf harvel pvc schedule 80 pipe and fittings exhibit consistent quality with uniform properties.
Maximum pressure ratings for pipes per.
Astm d2467 04e1 standard specification for poly vinyl chloride pvc plastic pipe fittings schedule 80 1 psi lb in 2 6 894 8 pa n m 2 1 inch 25 4 mm.
This is well above the 65 psi found in standard water systems.
To calculate elevated temperature rating use the following formula.
Max pressure 73 x derating factor schedule 80 pipe pvc pipe operating temp f de rating factor 73 1 00 80 0 88 90 0 75 100 0 62 110 0 51 120 0 40 130 0 31 140.
Schedule 80 pvc technical information schedule 80 pvc pipe dimensions pressure ratings made in the u s a.
Schedule 80 pvc technical information schedule 80 pvc pipe dimensions pressure ratings made in the u s a.
Gf harvel schedule 80 pvc systems are light tough and provide exceptional corrosion resistance for applications with operating temperatures up to 140 f 60 c.
Api 5l carbon steel pipe and a 106 a 53 a333 a334.
Pressure de rating at elevated temperatures the pressure ratings above are for water at 73 degrees fahrenheit.
Suitable for oil free air handling to 25 psi not for distribution of compressed air or gas page 336 due to material cost variations prices subject to change.
As with burst pressure the amount of collapse pressure pvc pipe can withstand decreases as size increases.
It can withstand a substantial amount of exterior pressure.
This table defines the maximum pressure rating for the specified industry standard pipes schedule 160 schedule 40 and schedule 80.
The speci fi ed derating factors for pvc are suitable for pipe conveying water at.
It is also well above the 140 psi rating standard in schedule 40 pvc pipe.
Maximum pvc service temperature 140 f pressure de rating at elevated temperatures the pressure ratings given above are for water non shock 73 f.
Schedule 80 as is the case in all three strength measurements is much stronger than schedule 40 pvc.
Schedule 80 pvc pipe is rated for at least 200 psi at 73 degrees fahrenheit.
The chart below will illustrate the pressure derating of pvc as temperatures increase.
Minimum tensile strength 60 ksi 60000 psi.